Analysis of Total E. coli and Physico-Chemical Quality of Water in the Location of Sumber Wendit Lanang in Mangliawan Village, Malang Regency

Gallant Gestuyev, Ahmad Syauqi, Faisal Faisal

Abstract


Coliform bacteria including E. coli is an indicators of water pollution. The presence of these bacteria indicates contamination and decreased air quality. Wendit Lanang spring meets the daily water needs of the residents of Mangliawan Village. The purpose of this study was to determine the total E. coli and coliform and describe the physico-chemical conditions of the air. This research design used a survey method with a quantitative descriptive approach, analysis with quantitative descriptive statistics and Spearman correlation test. The object of the study was Wendit Lanang Spring Water with a number of samples taken from 3 Stations. The air quality parameters tested were total E. coli/coliform with the petrifilm method and supporting parameters physically (organoleptic test, TDS) and chemically (pH, DO, Cl2) based on the Regulation of the Minister of Health Number 2 of 2023. The total E. coli results at Station 1 were 0 CFU/100 ml, Station 2 were 3 CFU/100 ml, and Station 3 were 6 CFU/100 ml. The total coliform at Station 1 was 1 CFU/100 ml. Meanwhile, Station 2 had 11 CFU/100 ml. Then Station 3 had 43 CFU/100 ml. Physicochemically, the three samples met the quality standards for temperature, TDS, pH, and DO parameters. Meanwhile, the Cl2 parameter did not meet the standard. Organoleptically, all three air samples were colorless, tasteless, and odorless. At the Sumber Wendit Lanang location, the number of bacteria increased followed by a decrease in dissolved oxygen concentration. The best water quality was found at Station 1, but for daily air needs, it requires a boiling process before drinking.

Keywords: coliform, E. coli, petrifilm, water, water quality

ABSTRAK

Bakteri koliform termasuk E. coli adalah salah satu indikator pencemaran air. Keberadaan bakteri ini mengindikasikan adanya kontaminasi dan penurunan kualitas air. Sumber Wendit Lanang memenuhi kebutuhan air sehari-hari bagi warga Desa Mangliawan. Tujuan dari penelitian ini adalah untuk menentukan total E. coli dan koliform serta deskripsi kondisi fisika-kimia air. Rancangan penelitian menggunakan metode survei dengan pendekatan kuantitatif deskriptif dengan analisis statistik deskriptif kuantitatif dan uji korelasi Spearman. Objek penelitian adalah air Sumber Wendit Lanang dengan jumlah sampel yang diambil dari 3 Stasiun. Parameter kualitas air yang diuji berupa total E. coli/koliform dengan metode petrifilm dan parameter penunjang secara fisika (uji organoleptik, TDS) dan kimia (pH, DO, Cl2) berdasarkan Peraturan Menteri Kesehatan Nomor 2 Tahun 2023. Hasil total E. coli pada Stasiun 1 sebesar 0 CFU/100 ml, Stasiun 2 sebesar 3 CFU/100 ml, serta Stasiun 3 sebesar 6 CFU/100 ml. Total koliform pada Stasiun 1 sebanyak 1 CFU/100 ml. Sedangkan Stasiun 2 sebanyak 11 CFU/100 ml. Kemudian Stasiun 3 sebesar 43 CFU/100 ml. parameter suhu, TDS, pH, dan DO pada ketiga sampel memenuhi standar baku mutu. Sedangkan pada parameter Cl2, tidak memenuhi standar. Secara organoleptik, ketiga sampel air tidak berwarna, tidak berasa, dan tidak berbau. Di lokasi Sumber Wendit Lanang, jumlah bakteri semakin banyak diikuti konsentrasi oksigen terlarut yang menurun. Kualitas air paling baik terdapat pada Stasiun 1 tetapi untuk kebutuhan air sehari-hari perlu proses pemasakan sebelum diminum.

  

    Kata kunci: air, E. coli, koliform, kualitas air, petrifilm



Full Text:

PDF

References


Syauqi, A. (2017). Mikrobiologi Lingkungan, Peranan Mikroorganisme Dalam Kehidupan. Yogyakarta: Penerbit ANDI.

Tambi, A., Brighu, U., & Gupta, A. (2023). Methods for detection and enumeration of coliforms in drinking water: a review. Water Supply, 23(10), 4047–4058. DOI:10.2166/ws.2023.247

Rohmawati, Y., & Kustomo. (2020). Analisis Kualitas Air pada Reservoir PDAM Kota Semarang Menggunakan Uji Parameter Fisika, Kimia, dan Mikrobiologi, serta Dikombinasikan dengan Analisis Kemometri. Walisongo Journal of Chemistry, 3(2), 100-107. DOI:10.21580/wjc.v3i2.6603

Badan Kebijakan Pembangunan Kesehatan. (2023). Survei Kesehatan Indonesia (SKI) 2023. Jakarta: Kementerian Kesehatan Republik Indonesia. Retrieved from https://www.badankebijakan.kemkes.go.id/hasil-ski-2023/

Permenkes. (2023). Peraturan Menteri Kesehatan Republik Indonesia Nomor 2 Tahun 2023 tentang Peraturan Pelaksanaan Peraturan Pemerintah Nomor 66 Tahun 2014 tentang Kesehatan Lingkungan. Jakarta: Kementerian Kesehatan Republik Indonesia.

Wulandari, A., Noer, S., & Parwati, E. (2024). Dampak Ecotourism terhadap Kualitas Air secara Mikrobiologis di Setu Babakan, Jagakarsa. EduBiologia, 4(1), 20-26. DOI:10.30998/edubiologia.v4i1.22149

3M Food Safety. (2017). 3M Petrifilm E. coli/Coliform Count Plate Interpretation Guide. St. Paul, USA: 3M Center. Retrieved from 3M.com/foodsafety.

Peng, Z., Wang, X., Huang, J., & Li, B. (2024). Chapter 53 - Pathogenic Escherichia coli. Molecular Medical Microbiology (Third Edition), 1065-1096. DOI:10.1016/B978-0-12-818619-0.00069-1.

Khan, F., & Gupta, R. (2020). Escherichia coli (E. coli) as an Indicator of Fecal Contamination in Groundwater: A Review. Environmental Science and Engineering, 225-235. DOI:10.1007/978-3-030-45263-6_21

Mufida, D. (2025). BAB 4 PATOGENESIS MIKROBA. In Nurhayati, A. Rahmanto, D. Septiani, D. Mufida, Khariri, B. Sanjaya, . . . I. Fidhatami, Mikrobiologi Kedokteran (p. 59). Padang: Azzia Karya Bersama.

Nainggolan, Y., Sugiyani, T., Nababan, J., Simbolon, W., & Hermyantiningsih, D. (2024). Analisa Pengaruh Suhu, Ph Dan TDS Terhadap Kualitas Air Di Sungai Kahayan Kalimantan Tengah. Prosiding Seminar Nasional Sains dan Teknologi Seri 02 Fakultas Sains dan Teknologi Universitas Terbuka. 1, pp. 913-919. Jakarta: Universitas Terbuka.

Departemen Kesehatan Republik Indonesia. (2010). Peraturan Menteri Kesehatan Republik Indonesia Nomor 492/Menkes/Per/IV/2010 tentang Persyaratan Kualitas Air Minum. Jakarta: Depkes RI.

Heath, R. C. (1983). Basic ground-water hydrology. U.S. Geological Survey Water-Supply Paper 2220.

Lung, W. (2022). Coliforms, Pathogens, and Viruses. In Water Quality Modeling That Works (pp. 203-230). Cham: Springer International Publishing. DOI:10.1007/978-3-030-90483-8_6

Kholifah, N., Syauqi, A., & Faisal. (2025). Studi Pencemaran E. coli Menggunakan Metode Petrifilm dan Lingkungan Mikrobiologis di Penampungan Air Tirto Lesti di Desa Poncokusumo. e-Jurnal Ilmiah SAINS ALAMI (Known Nature), 8(1), 28-35. DOI:10.33474/j.sa.v0i0.000000

Syahwarani, N., & Milenia, P. (2025). Analisis Kandungan Klorin Bebas (Cl₂) Pada Air Minum Dalam Kemasan Megavin Menggunakan Multiparameter Photometer. DE FACTO: Journal Of International Multidisciplinary Science, 3(2), 88-95. DOI:10.62668/defacto.v3i02.1726




DOI: http://dx.doi.org/10.33474/jimsum.v4i2.31586

Refbacks

  • There are currently no refbacks.


Publisher:
Fakultas Matematika dan Ilmu pengetahuan Alam Universitas Islam Malang
Jl MT. Haryono No.193, Gedung B Lt. 1.

Editorial Address:
Jalan Mayjen Haryono No.193, Dinoyo, Kec. Lowokwaru, Kota Malang, Jawa Timur 65144


Lisensi Creative Commons
Ciptaan disebarluaskan di bawah Lisensi Creative Commons Atribusi 4.0 Internasional.